Optimization Results

The following sections provide detailed overview on the numerical an graphical results regarding the LossLC analysis.

Integrated Global Results

IGR [€ or t_CO2]

cllp

fine

omf

ppsa

capex (ppcd)

0

0

0

0

costs (sim)

202437193

202259102

202259102

202259102

emissions (sim)

441567

443159

443159

443159

opex (ppcd)

202437194

202259103

202259103

202259103

The Integrated Global Result bar plots are created using the code below.

Image showing the CompC costs IGR as bar chart Image showing the CompC non_costs IGR as bar chart

Installed Capacity

Capacity [MW or MWh]

cllp

fine

omf

ppsa

BHKW

[13513.696969697, 8576.0]

[13513.697, 8576.0]

[8576.0, 13513.69697]

[13513.69697, 8576.0000001923]

Biogas

variable

variable

variable

variable

Biogas plant

25987

25987

25987

25987

Car charging Station

3473

3473

3473

3473

Coal Supply

102123

102123

102123

102123

Coal Supply Line

variable

variable

variable

variable

Commercial Demand

41969

41969

41969

41969

District Heating

variable

variable

variable

variable

District Heating Demand

50000

50000

50000

50000

Gas Station

45325

45325

45325

variable

Gaspipeline

variable

variable

variable

variable

GuD

26742

26742

26742

26742

HKW

[61273.96, 24509.584]

[61273.998, 24509.599]

[61273.96, 24509.6]

[61273.96, 24509.584]

HKW2

43913

43913

43913

43913

High Voltage Grid

variable

variable

variable

variable

High Voltage Transfer Grid

variable

0

variable

72141

Household Demand

36177

36177

36177

36177

Industrial Demand

63093

63093

63093

63093

Low Voltage Grid

variable

variable

variable

variable

Low Voltage Transfer Grid

variable

54703

variable

54703

Medium Voltage Grid

variable

variable

variable

variable

Offshore Wind Power

18760

18760

18760

18760

Onshore Wind Power

66599

66599

66599

66599

Power to Heat

50000

50000

50000

50000

Solar Panel

99605

99605

99605

99605

Solar Thermal

14343

14343

14343

14343

High Voltage Grid Summed Loads

Load-High Voltage Grid [MW]

cllp

fine

omf

ppsa

GuD

-116538

-121996

-121996

-121996

HKW

-235375

-237669

-237669

-237669

HKW2

-205713

-201601

-201601

-201601

High Voltage Transfer Grid

0

0

0

0

High Voltage Transfer Grid

867448

871089

871089

871089

Offshore Wind Power

-309821

-309821

-309821

-309821

Medium Voltage Grid Summed Loads

Load-Medium Voltage Grid [MW]

cllp

fine

omf

ppsa

Car charging Station

37026

37026

37026

37026

High Voltage Transfer Grid

-867448

-871089

-871089

-871089

High Voltage Transfer Grid

0

0

0

0

Industrial Demand

1229008

1229008

1229008

1229008

Low Voltage Transfer Grid

-111125

-111125

-111125

-111125

Low Voltage Transfer Grid

640388

644028

644028

644028

Onshore Wind Power

-1099866

-1099866

-1099866

-1099866

Power to Heat

172017

172017

172017

172017

Low Voltage Grid Summed Loads

Load-Low Voltage Grid [MW]

cllp

fine

omf

ppsa

BHKW

-12414

-8774

-8774

-8774

Commercial Demand

582459

582459

582459

582459

Household Demand

552564

552564

552564

552564

Low Voltage Transfer Grid

-640388

-644028

-644028

-644028

Low Voltage Transfer Grid

111125

111125

111125

111125

Solar Panel

-593346

-593346

-593346

-593346

District Heating Summed Loads

Load-District Heating [MW]

cllp

fine

omf

ppsa

BHKW

-19562

-13825

-13825

-13825

District Heating Demand

865459

865459

865459

865459

HKW

-588437

-594174

-594174

-594174

Power to Heat

-172017

-172017

-172017

-172017

Solar Thermal

-85441

-85441

-85441

-85441